Changing WX Connection Settings 551
3 To change the number of seconds the monitoring service waits for a TCP
connection with a WX switch to reach the Connect stage, type or select
the value in the Connect Timeout box. You can specify from 1 to 30
seconds. The default is 15 seconds.
4 To change the number of times the monitoring service will reattempt to
query a WX switch, if the monitoring service does not receive a reply to
the first query attempt within the connect timeout, type or select the
value in the Retry Count box. You can specify from 0 to 5 retries. The
default is 5 retries.
5 To prevent the monitoring service from accepting all types of certificates
from the WX switches it monitors, click Accept all certificates to disable
the option.