170 CHAPTER 4: PLANNING THE 3COM MOBILITY SYSTEM
■ To generate network design information, see “Generating RF Network
Design Information” on page 171.
■ Click Finish to save the changes and close the wizard.
Using RF Interactive
Measurement Mode
RF interactive measurement mode is useful when you are troubleshooting
or surveying the coverage areas on the floor. You can quickly measure
signal strengths for any location on the floor.
To use the RF interactive measurement mode
1 On the Plan RF Coverage page, click in the toolbar.
2 Click any location on the floor. Received signal strength indication (RSSI)
measurements for the selected location appear next to the View tab. See
“Reading the RF Measurement Table” for information about the fields in
the display.
Reading the RF
Measurement Table
The projected signal strengths for the planned equipment from that
measurement point are shown in the RF measurement table.
X-Y coordinates for the measurement point and display options are also
available to customize the RSSI table. Using this interactive mode can be
valuable when verifying deployment coverage with a portable WLAN
measurement tool on the floor.
Table 19 shows the information available in the RF measurement table.
Table 19 RF Measurement Information
Item Value
X Distance in the X direction from the 0,0 coordinate (the
upper left corner of the panel).
Y Distance in the Y direction from the 0,0 coordinate (the
upper left corner of the panel).
Show Unreachable
MAPs
Show MAP access points that are too far away to
accurately measure signal strength.
Show Disabled MAPs Show all disabled MAP access points.
Show MAPs on Other
Floors
Show the MAPs located on other floors that can be
detected from this RF measurement point.
MAP/AP MAP or third-party access points detected.
Distance Distance between MAP and RF measurement point.
Channel Channel of the MAP or third-party access point.