Parameters 191
02.10 FBA MAIN CW
Control Word for fieldbus communication. - / Pb
0x0000000...
0xFFFFFFF
Fieldbus control word. 1 = 1
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)
Bit Name Value Information Log. Par.
(continued)
9 JOGGING
1**
1 Activate jogging function 1.
OR
0 Jogging function 1 disabled.
10 JOGGING
2**
1 Activate jogging function 2.
OR
0 Jogging function 2 disabled.
11 REMOTE
CMD
1 Fieldbus control enabled.
0 Fieldbus control disabled.
12 RAMP
OUT 0
1 Force output of Ramp Function Generator to
zero. The drive ramps to a stop (current and
DC voltage limits are in force).
––
0 No action.
13 RAMP
HOLD
1 Halt ramping (Ramp Function Generator output
held).
––
0 No action.
14 RAMP IN 0 1 Force Ramp Function Generator input to zero.
––
0 No action.
15 RESERVED
16 REQ
STARTINH
1 Activate start inhibit.
––
0 No start inhibit.
17 LOCAL
CTL
1 Request local control for Control Word. Used
when the drive is controlled via PC tool or
panel or through local fieldbus.
Local fieldbus: Transfer to fieldbus local
control (control via fieldbus Control Word or
reference). Fieldbus steals the control.
Panel or PC tool: Transfer to local control.
––
0 Request external control.
18 FBLOCAL
REF
1 Request fieldbus local control.
––
0 No fieldbus local control.
19...
26
RESERVED
27 NOT USED
28...
31
CW
B28...B31
Freely programmable control bits.
** Internally used for evacuation and inspection mode operation.