276 Parameters
91.16 SSI TRANSMIT
CYC
Selects the transmission cycle for an SSI encoder.
Note: This parameter needs to be set only when an
SSI encoder is used in the continuous mode, that is
SSI encoder without incremental sin/cos signals
(supported only as encoder). The SSI encoder is
selected by setting parameter 91.02 ABS ENC
INTERF to SSI.
100 us /
UINT32
50 us 50 µs. 0
100 us 100 µs. 1
200 us 200 µs. 2
500 us 500 µs. 3
1 ms 1 ms. 4
2 ms 2 ms. 5
91.17 SSI ZERO PHASE
Defines the phase angle within one sine/cosine
signal period that corresponds to the value of zero on
the SSI serial link data. The parameter is used to
adjust the synchronization of the SSI position data
and the position based on sine/cosine incremental
signals. Incorrect synchronization may cause an
error of ±1 incremental period.
Note: This parameter needs to be set only when an
SSI encoder with sine/cosine incremental signals is
used in the initial position mode.
315-45 deg
/UINT32
315–45 deg 315–45 degrees. 0
45–135 deg 45–135 degrees. 1
135–225 deg 135–225 degrees. 2
225–315 deg 225–315 degrees. 3
91.18 ENDAT MODE
Selects the EnDat encoder mode.
Note: This parameter needs to be set only when an
EnDat encoder is used in the continuous mode, that
is EnDat encoder without incremental sin/cos signals
(supported only as encoder). The EnDat encoder is
selected by setting parameter 91.02 ABS ENC
INTERF to EnDat.
Initial pos. /
UINT32
Initial pos. Single position transfer mode (initial position). 0
Continuous Continuous position data transfer mode. 1
Cont.spd+pos Continuous speed and position transfer mode. 2
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACL30 and is the answer not in the manual?

ABB ACL30 Specifications

General IconGeneral
BrandABB
ModelACL30
CategoryDC Drives
LanguageEnglish

Related product manuals