U511 User’s Manual Programming Commands
Version 1.1 Aerotech, Inc. 5-85
X1.099 Y0.987 OU0x55 ;Incremental motion in 123 ms. At the end of the motion,
;the output command of 0x55 is executed, turning ON
;output bits 0,2,4, and 6
SPLINE OFF ;Splining is turned OFF
Related commands
INDEX, CW_CIRCLE, CCW_CIRCLE, FREERUN, G90, G91, G70, G71, PROGRAM
5.5.75. START
The START command is used to activate planes that are currently under the HALT
command.
SYNTAX:
START plane
START wait,plane, ...
plane Identifies the planes (1, 2, 3, and 4) that require a start.
wait Wait until designated planes go into the halt state, then starts
all of them.
The START command can be used only to activate planes other than its own.
EXAMPLE:
START 1,2 ;Activates planes 1 and 2 if they are on HALT
START WAIT,1,2 ;Wait until planes 1 and 2 go into halt state, then start both
;of them. If either or both planes 1 and 2 are not yet in the
;HALT state, WAIT will continue indefinitely
Related commands:
WAIT, HALT, MAP
E