Parameters U511 User’s Manual
4-20 Aerotech, Inc. Version 1.1
4.5.4. “Positive (+) jog same as + move” (y/n)
Each axis of the UNIDEX 511 may be configured such that either a positive or negative
jog command results in motion in the same or opposite direction as the “Positive (+)
move is CW” (x11) parameter.
This parameter can be set to either yes or no. Descriptions are given in Table 4-11.
Table 4-11. Settings for Parameter x12
Param # Axis # Description
x12 1, 2, 3, 4 Yes - A positive jog results in motion that is in the same
direction as specified by the “Positive (+) move is
CW” parameter
No - A positive jog results in motion that is in the opposite
direction as specified by the “Positive (+) move is
CW” parameter
4.5.5. “Enable pause in freerun” (y/n)
This parameter is used to enable or disable the pause function when the associated axis is
in freerun.
This parameter can be set to either yes or no. Descriptions are given in Table 4-12.
Table 4-12. Settings for Parameter x13
Param # Axis # Description
x13 1, 2, 3, 4 Yes - Pause function is enabled during freerun of the
associated axis (default)
No - Pause function is disabled during freerun of the
associated axis
x12
x13