U511 User’s Manual Remote Mode Operations
Version 1.1 Aerotech, Inc. 6-25
6.4.21. GV: Software Version
The GV remote command returns the current software version as an ASCII string. This is
the same version number that is displayed on the U511’s Startup screen. The version
consists of a major version and a minor version separated by a decimal point. The
sequence of communications for the GV command is shown in Table 6-35.
Table 6-35. Software Version Command Sequence
Direction of Transfer Command Description
Host→U511
GV Software Version command
Host→U511
EOS character End of string character (LF)
U511→Host
ACK/NAK character Acknowledge character (0x06)
Example: GV<EOS character>; U511 returns 5.00<EOS character>