Installer manual AlphaVision ML Rev. 3.60 01-01-2015 48
detector will resume from the sleep mode if there no detection observed for 2 minutes. If activity in the
detection area has occurred, wait at least 2 minutes before entering the area. All PowerCode 868MHz
Visonic detectors have a special test mode to suspend the sleep mode temporarily.
During the walk test the buzzer of the keypad will sound four long tones to indicate that the zone was
activated. This is an acoustic aid for the installer. If the AlphaVision ML has been expanded with a plug-on
speech board and a keypad with integrated speakers and a microphone, an external 4-8 ohm speaker of a
speaker then the voice prompt ‘Zone open’ followed by the zone name will be heard through the speaker(s).
View open zones
After a full walk test was performed on all zones, the supervisor can view a list of all activated zones on the
LCD display by pressing the <#/OK> button. All zones that were activated during the walk test are now
displayed individually, the top line of the LCD display shows the zone number and field strength (RF = 099)
and on the bottom line the zone name is displayed. For hard-wired zones the field strength indicator 'is
meaningless and will always be displayed as RF = 099. Make sure all connected zones are present in the list.
To exit the walk test function, press the button twice.
►! The field strength of wireless zones (RF value) must have a minimum value of 30. If the field strength
is below 30, it is recommended to select a different location for the wireless component or use a MCX-610
repeater (art.nr. 007110).
►! Upon exiting the walk test mode the fire reset output will automatically be activated.
Test LED & LCD
The supervisor has the ability to test the display and the status LEDs of the keypad via the "TEST LED & LCD"
function in the maintenance menu. Go through the options step by step to ensure all LED’s, LCD display and
keys on the keypad work correctly.
IP connection
The supervisor has the ability to establish a IP connection between the AlphaVision ML control panel and
the laptop / computer of the installer where the Alpha Tool software is installed. In this remote access can
be done without the need for changing firewall settings and port forwarding in the router of the end-user.
Installer access
The supervisor can use this option to determine whether the installer has direct access to the installer menu
or access is only possible via the user menu.
Send testreport
The supervisor has the option to manually send a testreport to the monitoring station. The installer can ask
you to perform this option.
Access via APP (V2.00 and above)
A mobile application (APP) is available for the AlphaVision ML. The supervisor must indicate whether the
APP has permission to connect to the AlphaVision ML.
APP key
Together with the mobile application (APP) a unique key must be programmed. This unique key should be
programmed both in the AlphaVision ML and in the mobile application (APP). The key is checked when the
app establishes a connection with the AlphaVision ML.