Installer manual AlphaVision ML Rev. 3.60 01-01-2015 71
the monitoring station will be delayed 30 seconds. If the user succeeds to disarm the system within
the extra 30 seconds alarm reporting will be aborted.
! From firmware version 3.30 entry and exit delays can be programmed as 3 digits from 0-999
seconds. When the EN50131 option is enable all entry and exits delays will automatically be limited
to 90 seconds !
! From firmware version 3.2 it is possible to arm the system with a low battery. This works only if the
Exit / Entry Mode (S-50131) is disabled.
LS on walktest (V2.00 and higher)
The ‘LS on walktest option is available as a tool for the installer to momentarily trigger (1 toon for alarm, 2
tones for tamper) the Loudspeaker(LS) output every time a zone is activated during the walktest mode. This
is especially useful in situations where the walktest is performed by one person.
! The LS output of connected I / O modules with power supply (Art. code. 004312) are also activated
during a walking test if this option is enabled.
Supervision Loud Alarm (V2.00 and higher)
The loud alarm can be suppressed when a supervision alarm occurs. According to the new EN50131
guidelines a supervision alarm is equal to a tamper alarm and a alarm should be triggered once a
supervision alarm occurs in an existing wireless detector. Since this is often undesirable in practice, the loud
alarm can be suppressed using a programming option. Default setting is ON
Doorbell via LS (V3.00 and higher)
Here you can determine whether the loudspeaker (LS) output will generate a doorbell signal when a zone
that is characterized as ‘doorbell zone’ is disrupted when the system is disarmed.
! The LS output of connected I / O modules with power supply (Art. code. 004312) are also activated if
this option is enabled.
EOL Resistor (V3.20 and higher)
The AlphaVision ML control panel supports various EOL resistor values next to the standard Alphatronics
(1k8 / 10K / 39K) resistors. Which EOL resistor configuration is used can be programmed here, the available
EOL configurations are as follows:
Brand
Alarm loop
Alarm contact
Anti-mask contact
Alphatronics
1K8
10K
Alphatronics (+AM)
1K8
10K
39K
Aritech
4K7
4K7
Galaxy
1K
1K1
3K
Galaxy (+AM)
1K1
1K1
2K2
ASB
5K6
5K6
NetworX
3K3
3K3
Scantronics
4K7
2K2
Guardall
8K2
8K2
Bosch
8K2
3K9
Aritech / Europlex
2K2
2K2
Aritech 10K
10K
10K
Galaxy
1K
1K
12K