EasyManua.ls Logo

alphatronics AlphaVision ML - Time Switch (V3.20 and Above); Users

alphatronics AlphaVision ML
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer manual AlphaVision ML Rev. 3.60 01-01-2015 43
Time switch (V3.20 and above)
The time switch function can be used to automatically arm/disarm the system at pre-programmed times.
The time switch function can be programmed in the user menu and is accessible for all users codes level 5
and higher. An arming and disarming time can be programmed for each day of the week including the
section(s) that must be armed/disarmed.
In order to alert users that an automatic arming will take place the time switch function is equipped with a
pre-arming signal. The pre-arming signal is heard through the loudspeaker ( LS output) and in practice it will
usually be heard a few minutes before the actual automatic arming takes place. When programming the
switching on and off the alarm time is also programmed.
The time switch programming screen on the keypad is as follows :
D00:00 A00:00
P00: 00 S.... N
D00:00 is the disarming time in the morning
A00:00 is the arming time in the evening
P00:00 is the pre-arming signal time, often several minutes for the switch (A00:00) .
S.... is the section(s) that is armed/disarmed .
An example of an actual time switch programming for all working days ( not include Saturday and Sunday )
is as follows :
D08:30 A18:30
P18: 25 S12.. N
The AlphaVision ML will disarm section 1 and 2 every weekday at 08:30. At 18:25 on every weekday a pre-
arming signal will be heard through the speaker, the pre-arming signal will be heard every minute (18:26 ,
18:27 , etc. . ) up until 18:30 in which the system will automatically arm section 1 and 2.
Users
In the submenu ‘Users’ you can program/modify user codes and/or proximity tag’s for all users of the
system. Up to 90 user codes/proximity tag’s can be created in the AlphaVision ML. For Proximity tag’s a
LCD/Proximity keypad must be present. Per user (code/tag) the following criteria need to be set:
code
level
days (of the week valid)
section(s)
user name
Always program the user code as a 6-digit code. From firmware V2.01 and above it is also possible to use 4-
digit codes. Always enter the code as a 6-digit code, when using 4-digit codes the first four (4) digits will be
recognized as a valid code, the last 2 digits are ignored.
!
From software version 2.01 and above the AlphaVision ML is protected against the programming of
the same user code twice.

Table of Contents