Installer manual AlphaVision ML Rev. 3.60 01-01-2015 65
Option 1
Go to the installer menu 'TIMERS' and select the desired output (1-8) that is programmed as ‘TRIGGER
OUTPUT’. Program an activation time of between 001 and 999 seconds. The output will now react as a
toggle output.
Once a random level 1 PIN-code is entered on a keypad the ‘trigger output’ is activated. Only after entering
a level 1 PIN-code again on a keypad will deactivate the ‘trigger output’.
By pressing the AUX (*) button on a keyfob transmitter the "trigger output" will be activated. By pressing
the AUX (*) button again the output will be deactivated.
If the ‘trigger output is activated by a (mobile) phone remotely, after the user has established a connection
with the AlphaVision ML he/she can DTMF key 7 (activate) and DTMF key 8 (deactivate) to activate and
deactivate the output.
! When using the option in the AlphaVision ML to activate the ‘trigger output’ using a (mobile)
telephone it is necessary to equip the mainboard with a speech plug-on board (art.code 004162).
Option 2
Go to the installer menu 'TIMERS' and select the desired output (1-8) that is programmed as ‘TRIGGER
OUTPUT’ and program an activation time of 000 seconds. The output will now react as a pulse (approx. 3
seconds) output.
Once a random level 1 PIN-code is entered on a keypad the trigger output will be activated for about 3
seconds.
By pressing the AUX (*) button on a keyfob transmitter then the trigger output’ will be activated for about 3
seconds.
If the ‘trigger output is activated by a (mobile) phone remotely, after the user has established a connection
with the AlphaVision ML he/she can use DTMF key 7 or 8 to activate the trigger output for about 3
seconds.
For further information about calling to the AlphaVision ML control refer to chapter ring-inin the remote
service section of the dialer programming.
! When using the option in the AlphaVision ML to activate the ‘trigger output’ using a (mobile)
telephone it is necessary to equip the mainboard with a speech plug-on board (art.code 004162).