123
3.3.1.10. Aggregate Power Control Tolerance
3.3.1.10.1. MT8820C
[Measurements]
1. [PCC/SCC] Execute TESTPRM TX_PCTAGG_PUSCH to set Test Parameter to TX3 Aggregate Power (PUSCH
Subtest).
2. [PCC/SCC] Execute SWP to measure the Power Control Tolerance (Aggregate Power).
3. [PCC/SCC] Execute PCTPWR? to read the Aggregate Power (dB) measurement result.
4. [PCC/SCC] Execute PCTPASS? to check that the Aggregate Power measurement Pass/Fail judgment is Pass.
5. [PCC/SCC] Execute TESTPRM TX_PCTAGG_PUCCH to set Test Parameter to TX3 Aggregate Power
(PUCCH Subtest).
6. [PCC] Execute SWP to measure the Power Control Tolerance (Aggregate Power).
7. [PCC] Execute PCTPWR? to read the Aggregate Power (dB) measurement result.
8. [PCC] Execute PCTPASS? to check that the Aggregate Power measurement Pass/Fail judgment is Pass.
3.3.1.10.2. MT8821C
[Measurements]
1. Execute TESTPRM TX_PCTAGG_PUSCH to set Test Parameter to TX3 Aggregate Power (PUSCH Sub-test).
2. Execute SWP to measure the Power Control Tolerance (Aggregate Power).
3. Execute PCTPWR? PCC to read the PCC Aggregate Power (dB) measurement result.
4. Execute PCTPASS? PCC to check that the PCC Aggregate Power measurement Pass/Fail judgment is Pass.
5. Execute PCTPWR? SCC1 to read the SCC1 Aggregate Power (dB) measurement result.
6. Execute PCTPASS? SCC1 to check that the SCC1 Aggregate Power measurement Pass/Fail judgment is Pass.
7. Execute TESTPRM TX_PCTAGG_PUCCH to set Test Parameter to TX3 Aggregate Power (PUCCH
Sub-test).
8. Execute SWP to measure the Power Control Tolerance (Aggregate Power).
9. Execute PCTPWR? PCC to read the PCC Aggregate Power (dB) measurement result.
10. Execute PCTPASS? PCC to check that the PCC Aggregate Power measurement Pass/Fail judgment is Pass.
3.3.1.11. Frequency Error
3.3.1.11.1. MT8820C
[Measurements]
1. [PCC/SCC] Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times.
2. [PCC/SCC] Execute TESTPRM RX_SENS to set Test Parameter to RX Ref. Sens./Freq. Error.
3. [PCC/SCC] Set UL RMC Number of RB.
4. [PCC/SCC] Execute SWP to measure the Modulation Analysis.
5. [PCC/SCC] Execute WORST_CARRFERR? HZ to read the Carrier Frequency Error (Hz) measurement result.
6. [PCC/SCC] Execute WORST_CARRFERR? PPM to read the Carrier Frequency Error (ppm) measurement result.
7. [PCC/SCC] Execute CARRFERRPASS? To check that the Carrier Frequency Error Pass/Fail judgment is Pass.
3.3.1.11.2. MT8821C
[Measurements]
1. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times.
2. Execute TESTPRM RX_SENS to set Test Parameter to RX Ref. Sens./Freq. Error.
3. Set UL RMC Number of RB.
4. Execute SWP to measure the Modulation Analysis.
5. Execute WORST_CARRFERR? HZ,PCC to read the PCC Carrier Frequency Error (Hz) measurement result.
6. Execute WORST_CARRFERR? PPM,PCC to read the PCC Carrier Frequency Error (ppm) measurement result.
7. Execute CARRFERRPASS? PCC to check that the PCC Carrier Frequency Error Pass/Fail judgment is Pass.
8. Execute WORST_CARRFERR? HZ,SCC1 to read the SCC1 Carrier Frequency Error (Hz) measurement result.
9. Execute WORST_CARRFERR? PPM,SCC1 to read the SCC1 Carrier Frequency Error (ppm) measurement
result.
10. Execute CARRFERRPASS? SCC1 to check that the SCC1 Carrier Frequency Error Pass/Fail judgment is Pass.