133
3.3.2.4. Configured UE transmitted Output Power for CA (intra-band contiguous DL CA and UL CA)
(6.2.5A.1)
3.3.2.4.1. MT8820C
This measurement item is not supported by the MT8820C.
Refere to Table 3.3-1.
3.3.2.4.2. MT8821C
[Pass/Fail evaluation limits value setting]
1. Execute PWR_AVG 20 to set the average count of Power measurement to 20 times.
2. Execute TP_CONFPWR1_TOL 7.7 (or TP_CONFPWR1_TOL 7.7, PCC) to set TX2 – Configured UE transmitted
Output Power (Test Point 1) Pass/Fail Judgment for PCC.
3. Execute TP_CONFPWR2_TOL 6.7 (or TP_CONFPWR2_TOL 6.7, PCC) to set TX2 – Configured UE transmitted
Output Power (Test Point 2) Pass/Fail Judgment for PCC.
4. Execute TP_CONFPWR3_TOL 5.7 (or TP_CONFPWR2_TOL 5.7, PCC) to set TX2 – Configured UE transmitted
Output Power (Test Point 3) Pass/Fail Judgment for PCC.
5. Execute TP_CONFPWR1_TOL 7.7, SCC1 to set TX2 – Configured UE transmitted Output Power (Test Point
1) Pass/Fail Judgment for SCC–1.
6. Execute TP_CONFPWR2_TOL 6.7, SCC1 to set TX2 – Configured UE transmitted Output Power (Test Point
2) Pass/Fail Judgment for SCC–1.
7. Execute TP_CONFPWR3_TOL 5.7, SCC1 to set TX2 – Configured UE transmitted Output Power (Test Point
3) Pass/Fail Judgment for SCC–1.
[Measurements]
8. Execute TESTPRM TX_CONF_PWR1 to set Test Parameter toTX2 – Configured Power (Test Point 1).
9. Execute ULRMC_RB_SCC1 0 to set Common Parameter – SCC-1 – UL RMC – Number of RB to 0.
10. Execute SWP to measure the power.
11. Execute POWER? AVG to read the TX Power measurement result.
12. Execute TESTPRM TX_CONF_PWR2 to set Test Parameter to TX2 – Configured Power (Test Point 2).
13. Execute steps 9 to 11.
14. Execute TESTPRM TX_CONF_PWR3 to set Test Parameter to TX2 – Configured Power (Test Point 3).
15. Execute 9 to 11.
NOTE 1: The tolerance (lower limit) is relaxed by 1.5dB for transmission bandwidths confined within F
UL_low
and F
UL_low
+ 4 MHz or F
UL_high
– 4 MHz and F
UL_high
.
NOTE 2: Pass/Fail judgment values vary depending on the Carrier Frequency f.
f – 3.0 GHz :pMax ±7.7 dBm (at Test Point 1)
: pMax ±6.7 dBm (at Test Point 2)
: pMax ±5.7 dBm (at Test Point 3)
3.0 GHz < f ≤ 4.2 GHz : pMax ±8.0 dBm (at Test Point 1)
: pMax ±7.0 dBm (at Test Point 2)
: pMax ±6.0 dBm (at Test Point 3)