5.2.5.1. MT8820C
[Procedure]
The PCC setting is indicated in red bold [PCC], and the SCC setting is indicated in blue bold [SCC].
[MT8820C PCC]
1. [PCC] Execute PRESET to set default parameter.
2. [PCC] Execute CALLPROC ON to set Call Processing to On.
3. [PCC] Execute BANDWIDTH 20MHZ to set Common Parameter - Channel Bandwidth to 20 MHz.
4. [PCC] Execute DLCHAN 300 to set Common Parameter - UL Channel and DL Channel to 18300 and 300,
respectively.
5. [PCC] Execute CHCODING PACKET_DL_CA_PCC to set Common Parameter - Channel Coding to Packet (DL
CA - PCC).
6. [PCC] Execute ANTCONFIG OPEN_LOOP to set Common Parameter - Antenna Configuration to 2x2MIMO
(Open Loop).
7. [PCC] Execute ULRMC_RB 100 to set Common Parameter - UL RMC - Number of RB to 100.
8. [PCC] Execute ULIMCS 23 to set Common Parameter - UL RMC - MCS Index to 23.
9. [PCC] Execute DLRB 100,0 to set Common Parameter - DL RMC - Number of RB to 100, and DL RMC -
Starting RB to 0.
10. [PCC] Execute DLIMCS1 28, DLIMCS2 28 and DLIMCS3 28 to set Common Parameter - DL RMC - MCS
Index1/2/3 to 28.
11. [PCC] Execute BANDWIDTH_SCC1 20MHZ to set Common Parameter - SCC1 - Channel Bandwidth to 20
MHz.
12. [PCC] Execute DLCHAN_SCC1 498 to set Common Parameter - SCC1 - DL Channel to 498.
13. [PCC] Execute DLRMC_RB_SCC1 100 to set Common Parameter - SCC1 - DL RMC - Number of RB to 100.
14. [PCC] Execute DLIMCS1_SCC1 28, DLIMCS2_SCC1 28 and DLIMCS3_SCC1 28 to set All of SCC1 - DL RMC -
MCS Index1/2/3 to 28.
Note: The above four procedures are for the SCC setting. Set these parameters to match the MT8820C
settings.
MT8820C (PCC)
MT8820C (SCC)
Call Processing Parameter - SCC-1 - Channel
Bandwidth
Common Parameter - Channel Bandwidth
Call Processing Parameter - SCC-1 - DL
Channel
Common Parameter - DL Channel
Call Processing Parameter - SCC-1 - DL RMC
Number of RB
Common Parameter - DL RMC - Number of RB
Call Processing Parameter - SCC-1 - DL RMC -
MCS Index1/2/3
Common Parameter - DL RMC - MCS
Index1/2/3
15. [PCC] Execute SERVERIP 192,168,20,10 to set Call Processing Parameter - Packet - Server IP Address to
192.168.20.10.
16. [PCC] Execute CLIENTIP 192,168,20,11 to set Client IP Address 1 to 192.168.20.11.
17. [PCC] Execute CLIENTIP2 192,168,20,12 to set Client IP Address 2 to 192.168.20.12.
18. [PCC] Execute DEDEPSACT ON to set Dedicated EPS Bearer Activation to On.
19. [PCC] Execute LINKEPSID 5 to set Linked EPS Bearer Identity to 5. (Note 2)
20. [PCC] Execute TFTIPV4 192,168,20,100 to set TFT Remote IPv4 Address to 192.168.20.100.
21. [PCC] Execute TPUT_MEAS ON to set Throughput Measurement to On.
Note: Set Dedicated EPS Bearer Activation to On when verifying IP Data Transfer with carrier
aggregation.
Fig. 5.2.5.1-1 Parameter Setting for Dedicated EPS Bearer