Measuring Strategies
101
Measured angle can now be selected for measurement at peak torque, max. angle, or cycle complete
When using this strategy there is no need to be over-cautious in checking the installed torque with peak
strategy. Just pull the wrench with a uniform speed until the head is moving. ACTA will take care of the
analysis.
Wrench, Installed Torque
Torque
End Time
Installed
Torque
Torque Min
Torque Max
Time
Cycle Complete
Cycle Start
Click Wrench
Torque
Cycle
Start
Start Angle
Angle
End Time
Peak
Value
Torque Min
Torque Max
Angle Max
Angle Min
Slip Torque
Time
Cycle Complete

Table of Contents