Printouts from the ACTA 3000 
  141 
12.9  Tool calibration 
 
TOOL CALIBRATION REPORT  1(1) 
 
Tool identity  Date  Time 
AB865    Jun 28 20000  10:55.27 
 
Acta serial number  047001 
Transducer serial number  34539 
 
Number  Transducer  Controller  T Difference  T Difference 
  (Nm)  (Nm)  (Nm)  (%) 
12  15.77  15.20  0.575  3.64 
11  15.83  15.20  0.631  3.99 
10  15.90  15.20  0.702  4.42 
9  15.87  15.30  0.572  3.60 
8  15.85  15.20  0.654  4.12 
7  16.05  15.80  0.254  1.58 
6  15.97  15.20  0.766  4.80 
5  16.02  15.40  0.619  3.86 
4  15.78  15.20  0.575  3.65 
3  15.69  15.10  0.589  3.75 
2  15.98  15.20  0.777  4.86 
1  15.80  15.10  0.701  4.43 
 
MAX  16.05  15.80  0.777  4.86 
MIN  15.69  15.10  0.254  1.58 
MEAN  15.88  15.26  0.618  3.89 
RANGE  0.365  0.700  0.523  3.28 
SIGMA  0.111  0.188  0.135  0.85 
 
OLD CALIBRATION TORQUE:  17.02 Nm 
NEW CALIBRATION TORQUE:  17.61 Nm  UPDATED:  YES 
TOOL COMMENT  Tool OK 
 
ADDITIONAL INFORMATION  ............................................  
 
....................................................................  
 
ANGLE CHECKED  .....   .... 
  YES    NO 
 
TEST PERFORMED BY:  AJN 
 
SIGNATURE 
 
........................................