Measuring Strategies
99
9. Measuring Strategies
9.1 General
In the previous section we explained how to program your ACTA 3000. Now
let us look at examples of different measuring strategies. Below, you can see
how the measurement parameters in the “Program” menu block can be applied
when measuring different tools.
Note!
The curves displayed below do not fully represent actual tightening curves.
Their shapes are relevant only to illustrate the “Program” measurement
parameters
Measured angle can now be selected for measurement at peak torque, max. angle or cycle complete.
Time
Direct Driven Tools
Torque
Cycle Start
Start Angle
Peak
Value
Cycle Complete
Torque Min
Torque Max
Angle Max
Angle Min
Angle
End Time
End Time