Calibration
127
11.3.5 Power Focus 3000 calibration
Use Power Focus 3000 calibration to calibrate a Power Focus 3000 controller.
Torque tuning of Power Focus 3000 with Tensor DS tool connected is done in the same
way as torque tuning a DS controller (refer to DS calibration). Tool model Tensor S
connected, see the calibration description below.
A new calibration torque value will be calculated. The new value can be saved in the
controller if communication is set up to the controller. See the figure below.
Display text Comments
P-Set Parameter set used.
X-bar Mean torque value.
X-bar Contr. Mean controller torque. Values are manually
entered or read from controller. Manually
entered if communication not set up to
controller.
New cal. torque New calculated calibration torque for
controller.