EasyManua.ls Logo

Atlas Copco ACTA 3000

Atlas Copco ACTA 3000
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming
91
8.18.1 All Tightening operations
1. Open the Stat. menu block and a pop-up menu appears listing the above
options, 1 for Basic, or 1-4 for QC and AA versions.
2. The following are displayed in the dialog box:
Number
Torque
Angle
No. of pulses
Controller torque (C-trq)
Difference between torque and controller torque (T-diff)
3. Use the up, down, left and right arrows in the menu block area to scroll
through all your tightening operations.
When finished, press Cancel to return to the measurement dialog box.
4. The tightening operations are displayed with the first tightening operation
shown at the top.
8.18.2 Statistics torque
Open Stat. and select 2. Statistics Torque and a pop-up dialog box appears again.
These are your statistics for the torque. Each statistical parameter is calculated
on all measured tightening operations saved during the measurement of each
specific tool. Use the left and right arrows in the menu to scroll.
Statistics for all tightening operations
No. Number of tightening operations.
Min. Min. torque.
Max. Max. torque.
X X-bar (mean) torque.
R Range of torque.
CR CR (capability index) for torque.