Programming
79
8.9 Speed (Speed)
Available in Basic, Quality Control and Advanced Analysis versions.
If you are using a transducer that features an angle encoder you can measure the
peak and track speed of your tools, both free speed and during a tightening
operation.
1. Open the Speed menu block and a pop-up dialog box appears.
2. (Run your tool.)
3. The top figure is your peak speed and below it you can see your track
speed. Note the difference in track speed during a tightening operation.
8.10 User (User)
Available in Quality Control and Advanced Analysis versions.
When performing measurements, an alpha-numeric code can be added
(maximum four characters) to represent the user who is making the
measurements.
The user code is saved in the database for all tools that are tested, until a new
one is specified. The user code is displayed when the ACTA 3000 is in Custom
dialog box mode.
1. Open the User menu block and a pop-up dialog box appears.
2. Enter your code using the alpha-numeric keypad and then press ‘Enter’.
3. You can now see the user name in the bottom left corner of the display in
Custom dialog box mode.
To change the user name, repeat the above operation. If you wish to delete the
user code, open the User menu block and simply press ‘Enter’.