Measurement Results
103
10. Measurement Results
10.1 General
On the following pages we will examine the different measurement
windows and the information they provide during your measurement.
10.2 Basic Measurement Window
This is the standard window in ACTA 3000 Basic. It is also available in the
Quality Control and Advanced Analysis versions and can be selected under
the “View” menu block.
When initiating measurements this is the information it provides:
1 4 12 2
11 9
1. Power left in battery 7. Measured torque
2. Number of tightening operations 8. Measured angle
3. X-bar 9. Number of pulses
4. Unit 10. Last five tightening operations
5. Confidence interval neg. 11. Softkey text
6. Confidence interval pos. 12. Filter frequency
1. Power left in battery
This indicates how much power there is left in the
7
8
3
5
6
10