Technical Specifications
179
F2000/PF2000
1. Manual input
F2000/PF2000
Tool type Direct driven
Target torque 0.75 * Transducer calibration torque * Transducer torque span
Calibration torque 0.75 * Transducer calibration torque * Transducer torque span
Parameter set 0
Controller F2000/PF2000
Communication Manual input
Unit ID 0
Channel 1
Model Tensor S
Filter frequency 500 Hz
Rotation direction CW
Measure strategy Peak
Cycle start 0.05 * Transducer calibration torque
Cycle complete 0.10 * Transducer calibration torque
Start angle 0.12 * Transducer calibration torque
Angle complete Peak torque
Measure delay time 0 ms
Reset time 0 ms
End time 400 ms
Slip torque
13
0.1 Nm
Batch size 0
Subgroup size 5
Subgroup frequency 1
Batch result Off
Torque min. 0.05 * Transducer calibration torque
13
Not used for direct driven tool.