Programming
54
To select a position, use the up and down arrows to navigate the list or use the number keys.
Press the ‘Enter’ key when ready. With the ‘Del’ softkey the selected transducer information is
not displayed and marked as “not valid” internally. To edit a position, press the ‘Edit’ softkey. A
dialog box then appears with the following:
Sensitivity The sensitivity to 0.59, 0.8, 1.2, 1.475 or 2.0 mV/V.
Calibration torque The calibration torque of the transducer.
Angle encoder Angle encoder resolution. A value of 0 means no encoder.
Comment A string defining the transducer (displayed in list).
Serial number The serial number of the transducer (displayed in list).
Use this dialog box to set the parameters to the correct value for the transducer
used. This information should be found on the label of the transducer.
If it is missing:
§ Contact the manufacturer. To exit use the ‘OK’ button or use the arrow
keys to highlight OK
§ Select Field and press ‘Enter’. The parameter values will be saved in the
selected position.
Note!
The transducer database is saved in a non-volatile memory and the information will be kept
intact during power off. It is not possible to select a “not valid” position for usage (press
‘Enter’ to use this set of transducer data).