Version 6.2 335 February 2011
SIP User's Manual 10. Configuration Parameters Reference
Parameter Description
Each interface must have a unique VLAN ID.
Each interface must have a unique subnet.
Subnets in different interfaces must not overlap (e.g.,
defining two interfaces with 10.0.0.1/8 and 10.50.10.1/24 is
invalid). Each interface must have its own address space.
Upon device start up, this table is parsed and passes
comprehensive validation tests. If any errors occur during
this validation phase, the device sends an error message to
the Syslog server and falls back to a “safe mode”, using a
single IPv4 interface and without VLANs. Therefore, check
the Syslog for any error messages.
When booting using BootP/DHCP protocols, an IP address is
obtained from the server. This address is used as the OAMP
address for this session, overriding the address configured
using the InterfaceTable. The address specified for OAMP
applications in this becomes available when booting from
flash again. This enables the device to work with a
temporary address for initial management and configuration
while retaining the address to be used for deployment.
To configure multiple IP interfaces in the Web interface and
for a detailed description of the table's parameters, see
''Configuring IP Interface Settings'' on page 78).
For a description of configuring ini file table parameters, see
''Configuring ini File Table Parameters'' on page 194.
Single IP Network Parameters
Web: IP Address
EMS: Local IP Address
[LocalOAMIPAddress]
The device's source IP address of the operations,
administration, maintenance, and provisioning (OAMP) interface
when operating in a single interface scenario without a Multiple
Interface table.
The default value is 0.0.0.0.
Note: For this parameter to take effect, a device reset is
required.
Web: Subnet Mask
EMS: OAM Subnet Mask
[LocalOAMSubnetMask]
The device's subnet mask of the OAMP interface when
operating in a single interface scenario without a Multiple
Interface table.
The default subnet mask is 0.0.0.0.
Note: For this parameter to take effect, a device reset is
required.
Web: Default Gateway Address
EMS: Local Def GW
[LocalOAMDefaultGW]
The Default gateway of the OAMP interface when operating in a
single interface scenario without a Multiple Interface table.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS