Version 6.2 367 February 2011
SIP User's Manual 10. Configuration Parameters Reference
Parameter Description
[SNMPSysOid]
Defines the base product system OID.
The default is eSNMP_AC_PRODUCT_BASE_OID_D.
Note: For this parameter to take effect, a device reset is
required.
[SNMPTrapEnterpriseOid]
Defines a Trap Enterprise OID.
The default is eSNMP_AC_ENTERPRISE_OID.
The inner shift of the trap in the AcTrap subtree is added
to the end of the OID in this parameter.
Note: For this parameter to take effect, a device reset is
required.
[acUserInputAlarmDescription]
Defines the description of the input alarm.
[acUserInputAlarmSeverity]
Defines the severity of the input alarm.
[AlarmHistoryTableMaxSize]
Determines the maximum number of rows in the Alarm
History table. This parameter can be controlled by the
Config Global Entry Limit MIB (located in the Notification
Log MIB).
The valid range is 50 to 100. The default value is 100.
Note: For this parameter to take effect, a device reset is
required.
[SNMPEngineIDString]
Defines the SNMP engine ID for SNMPv2/SNMPv3
agents. This is used for authenticating a user attempting to
access the SNMP agent on the device.
The ID can be a string of up to 36 characters. The default
value is 00:00:00:00:00:00:00:00:00:00:00:00 (12 Hex
octets characters). The provided key must be set with 12
Hex values delimited by a colon (":") in the format
xx:xx:...:xx. For example,
00:11:22:33:44:55:66:77:88:99:aa:bb
Notes:
For this parameter to take effect, a device reset is
required.
Before setting this parameter, all SNMPv3 users must
be deleted; otherwise, the parameter setting is ignored.
If the supplied key does not pass validation of the 12
Hex values input or it is set with the default value, the
engine ID is generated according to RFC 3411.
Web: SNMP Trap Destination Parameters
EMS: Network > SNMP Managers Table
Note: Up to five SNMP trap managers can be defined.
SNMP Manager
[SNMPManagerIsUsed_x]
Determines the validity of the parameters (IP address and
port number) of the corresponding SNMP Manager used
to receive SNMP traps.
[0] (Check box cleared) = Disabled (default)
[1] (Check box selected) = Enabled

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS