EasyManuals Logo

AudioCodes MediaPack MP-124 User Manual

AudioCodes MediaPack MP-124
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #416 background imageLoading...
Page #416 background image
SIP User's Manual 416 Document #: LTRT-65415
MediaPack Series
Parameter Description
'a=rtpmap:100 X-NSE/8000'.
To use this feature:
9 The Cisco gateway must include the following definition:
'modem passthrough nse payload-type 100 codec
g711alaw'.
9 Set the Modem transport type to Bypass mode
(VxxModemTransportType is set to 2) for all modems.
9 Configure the gateway parameter NSEPayloadType =
100.
This parameter can also be configured per IP Profile, using
the IPProfile parameter (see ''Configuring IP Profiles'' on
page 122).
EMS: NSE Payload Type
[NSEPayloadType]
NSE payload type for Cisco Bypass compatible mode.
The valid range is 96-127. The default value is 105.
Note: Cisco gateways usually use NSE payload type of 100.
Web: V.21 Modem Transport Type
EMS: V21 Transport
[V21ModemTransportType]
V.21 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent) - default
[1] Enable Relay = N/A
[2] Enable Bypass.
[3] Events Only = Transparent with Events
Note: This parameter can also be configured per IP Profile,
using the IPProfile parameter (see ''Configuring IP Profiles'' on
page 122).
Web: V.22 Modem Transport Type
EMS: V22 Transport
[V22ModemTransportType]
V.22 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
Note: This parameter can also be configured per IP Profile,
using the IPProfile parameter (see ''Configuring IP Profiles'' on
page 122).
Web: V.23 Modem Transport Type
EMS: V23 Transport
[V23ModemTransportType]
V.23 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
Note: This parameter can also be configured per IP Profile,
using the IPProfile parameter (see ''Configuring IP Profiles'' on
page 122).
Web: V.32 Modem Transport Type
EMS: V32 Transport
[V32ModemTransportType]
V.32 Modem Transport Type used by the device.
[0] Disable = Disable (Transparent)
[1] Enable Relay = N/A
[2] Enable Bypass = (default)
[3] Events Only = Transparent with Events
Notes:
This parameter applies only to V.32 and V.32bis modems.
This parameter can also be configured per IP Profile, using
the IPProfile parameter (see ''Configuring IP Profiles'' on
page 122).

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS