SIP User's Manual 458 Document #: LTRT-65415
MediaPack Series
Parameter Description
Web: Silence Detection Period [sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeriod]
Duration of the silence period (in seconds) after which the
call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note: For this parameter to take effect, a device reset is
required.
Web: Silence Detection Method
[FarEndDisconnectSilenceMethod]
Silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
[2] Voice/Energy Detectors = According to energy and
voice detectors (default).
[3] All = According to packet count, and energy and
voice detectors.
Note: For this parameter to take effect, a device reset is
required.
[FarEndDisconnectSilenceThreshold]
Threshold of the packet count (in percentages) below
which is considered silence by the device.
The valid range is 1 to 100%. The default is 8%.
Notes:
This parameter is applicable only if silence is detected
according to packet count
(FarEndDisconnectSilenceMethod is set to 1).
For this parameter to take effect, a device reset is
required.
[BrokenConnectionDuringSilence]
Enables the generation of the BrokenConnection event
during a silence period if the channel’s NoOp feature is
enabled (using the parameter NoOpEnable) and if the
channel stops receiving NoOp RTP packets.
[0] Disable (default).
[1] Enable.
Web: Disconnect Call on Busy Tone
Detection
EMS: Disconnect On Detection End
Tones
[DisconnectOnBusyTone]
Determines whether a call is disconnected upon detection
of a busy tone.
[0] Disable = Do not disconnect call on detection of
busy tone.
[1] Enable = Call is released if busy or reorder (fast
busy) tone is detected on the device's FXO port
(default).
Notes:
This parameter is applicable only to FXO interfaces.
This parameter can also be configured per Tel Profile,
using the TelProfile parameter.

Table of Contents

Other manuals for AudioCodes MediaPack MP-124

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-124 and is the answer not in the manual?

AudioCodes MediaPack MP-124 Specifications

General IconGeneral
ModelMediaPack MP-124
CategoryGateway
ProtocolsSIP, H.323, MGCP
Voice CodecsG.711, G.723.1, G.726, G.729A/B
Fax SupportT.38
ManagementSNMP
SecurityTLS/SRTP
Power Supply100-240 VAC, 50/60 Hz
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-25 to 70°C
Humidity10% to 90%, non-condensing
Analog Ports24 FXS