Component Flag Description
The values are YES and NO. The
default value is NO (disabled).
Memory Monitor. MEMCHECK_PERIOD Determines the time period in seconds
when the Memory Monitor wakes up
(after start-up or the last memory check
attempt).
The values are 1800 (0.5 hrs) to
86400 (24 hrs). The default value is
86400 (24 hrs).
SIP-traffic monitor DOS_PACKET_RATE Determines the maximum number of
packets per second that is allowed.
SIP_traffic monitor DOS_MAX_LIMIT Specifies how many packets past
DOS_PACKET_RATE the IP
Deskphone can receive before packets
are dropped.
If packets are received at a rate of
DOS_PACKET_RATE +1, then
packets start getting dropped after the
time specified in DOS_MAX_LIMIT (in
seconds).
SIP-traffic monitor DOS_LOCK_TIME Specifies the amount of time (in
seconds) the IP Deskphone stops
processing packets after
DOS_MAX_LIMIT is reached.
If DOS_PACKET_RATE is < 1, other
values are ignored and packets are
not dropped.
Logging System LOGSIP_ENABLE Allows the administrator to enable or
disable SIP-logging.
If the parameter is YES, the SIP-
logging Manager is active and starts
logging SIP incoming and outgoing
packets into the log files in FFS.
The values are YES and NO. The
default value is NO (the manager is
not active and the IP Deskphone
does not log in SIP incoming and
outgoing packets.
Device configuration file
March 2015 SIP Software for Avaya 1200 Series IP Deskphones-Administration 357
Comments? infodev@avaya.com