Description and Usage GuidelinesDefaultField Type
or Choices
Field Name
Identifies the EnergyWise domain that the phone is in.Up to 127 charactersEnergyWise Domain
Identifies the security secret password that is used to
communicate with the endpoints in the EnergyWise domain.
Up to 127 charactersEnergyWise Secret
Determines whether you allow the EnergyWise domain
controller policy to send power level updates to the phones.
The following conditions apply:
•
One or more days must be selected in the Enable Power
Save Plus field.
•
The settings in Cisco Unified Communications Manager
Administration take effect on schedule even if
EnergyWise sends an override.
For example, assuming the Phone Off Time is set to 22:00
(10:00 p.m.), the value in the Phone On Time field is 06:00
(6:00 a.m.), and the Enable Power Save Plus has one or more
days selected.
•
If EnergyWise directs the phone to turn off at 20:00 (8:00
p.m.), that directive remains in effect (assuming no phone
user intervention occurs) until the configured Phone On
Time at 6:00 a.m.
•
At 6:00 a.m., the phone turns on and resumes receiving
the power level changes from the settings in Cisco
Unified Communications Manager Administration.
•
To change the power level on the phone again,
EnergyWise must reissue a new power level change
command.
To disable Power Save Plus, you must uncheck the Allow
EnergyWise Overrides check box. If the Allow EnergyWise
Overrides remains checked but no days are selected in the
Enable Power Save Plus field, Power Save Plus is not disabled.
UncheckedCheckboxAllow EnergyWise
Overrides
Cisco IP Phone 8800 Series Administration Guide for Cisco Unified Communications Manager
142
Phone Feature Configuration