Page #570 background image
2-544
Catalyst 2950 and Catalyst 2955 Switch Command Reference
OL-10102-01
Chapter 2 Catalyst 2950 and 2955 Cisco IOS Commands
vlan database
When you have modified VLAN or VTP parameters, you can use these editing buffer manipulation
commands:
abort: exits the mode without applying the changes. The VLAN configuration that was running
before you entered VLAN configuration mode continues to be used.
apply: applies current changes to the VLAN database, increments the database configuration
revision number, propagates it throughout the administrative domain, and remains in VLAN
configuration mode.
Note You cannot use this command when the switch is in VTP client mode.
exit: applies all configuration changes to the VLAN database, increments the database configuration
number, propagates it throughout the administrative domain, and returns to privileged EXEC mode.
no: negates a command or set its defaults; valid values are vlan and vtp.
reset: abandons proposed changes to the VLAN database, resets the proposed database to the
implemented VLAN database on the switch, and remains in VLAN configuration mode.
show: displays VLAN database information.
show changes [vlan-id]: displays the differences between the VLAN database on the switch and the
proposed VLAN database for all normal-range VLAN IDs (1 to 1005) or the specified VLAN ID (1
to 1005).
show current [vlan-id]: displays the VLAN database on the switch or on a selected VLAN (1 to
1005).
show proposed [vlan-id]: displays the proposed VLAN database or a selected VLAN (1 to 1005)
from the proposed database. The proposed VLAN database is not the running configuration until
you use the exit or apply VLAN configuration command.
You can verify that VLAN database changes have been made or aborted by using the show vlan
privileged EXEC command. This output is different from the show VLAN database configuration
command output.
Examples This example shows how to enter the VLAN configuration mode from the privileged EXEC mode and
to display VLAN database information:
Switch# vlan database
Switch(vlan)# show
Name: default
Media Type: Ethernet
VLAN 802.10 Id: 100001
State: Operational
MTU: 1500
Translational Bridged VLAN: 1002
Translational Bridged VLAN: 1003
Name: VLAN0002
Media Type: Ethernet
VLAN 802.10 Id: 100002
State: Operational
MTU: 1500

Table of Contents

Other manuals for Cisco Catalyst 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco Catalyst 2950 and is the answer not in the manual?

Cisco Catalyst 2950 Specifications

General IconGeneral
Forwarding Bandwidth8.8 Gbps
Switching Capacity13.6 Gbps
Forwarding Rate6.6 Mpps
Weight3.6 kg
RAM16 MB
Flash Memory8 MB
Operating Humidity10% to 85% non-condensing
Uplink Ports2 x 10/100/1000Base-T
Dimensions4.4 cm x 44.5 cm x 24.2 cm
Remote Management ProtocolSNMP, Telnet, HTTP
FeaturesQuality of Service (QoS), VLAN support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p
Status Indicatorssystem
Operating Temperature0 to 45°C
Ports24 x 10/100 Ethernet ports
MAC Address Table Size8, 192 entries
Power SupplyInternal 100-240V AC, 50-60Hz

Related product manuals