92 User Manual Synertia® RF Generator
The information contained in this manual is subject to change by Comet Yxlon without prior notice.
Table 28: Exception Function Codes
The exception code in the third byte of the response specifies the reason why the
request was rejected. The following table shows the meaning of each exception code.
The transmitted function code is invalid (not 0x41 or 0x42).
Address
The data address (Command Number) received in the request
is not an allowable address for the
receiver.
A value contained in the data field of the Request is not an
allowable value. This
indicates that the number of data bytes
received for requested command is incorrect. It explicitly does
not mean that the data value is outside the allowed limit for
the requested command.
The value that was sent is invalid.
The parameter is not writable (for read
-only parameters).
The parameter is not readable (for write-only parameters).
The parameter is not changeable while RF is on. Turn RF off
and send
the parameter again.
Writing this parameter is not allowed (insufficient rights).