User Manual Synertia® RF Generator 9
The information contained in this manual is subject to change by Comet Yxlon without prior notice.
1.3.3 Hot surface hazards
WARNING
This label is used on the product (only air-cooled generator) to indicate a
hazard due to hot surfaces.
Touching the hot surface can cause burns.
Safety note 5: Warning - hot surface
Safety instructions for the user
The following instructions must be observed by the user at any time:
Do not touch the surface of the generator when in operation.
1.3.4 Heavy weight hazards
WARNING
This label is used on the product to indicate a hazard due to heavy
weights.
Handling weights that are too heavy can cause muscle strain or back
injuries.
Safety note 6: Warning - heavy weight
Safety instructions for the user
The following instructions must be obeyed by the user at any time:
Air-cooled generator:
Use lifting aids and proper lifting technique to handle the generator.
Water-cooled generator:
Two persons or a mechanical lift are needed to lift the generator throughout
expected installation heights of 25,4 to 162 cm / 10 to 64 in. Using a 35,5 cm / 14 in
high step stool allows two-person lifting-up to an installed height of 193 cm /
76 in. See also section 3.1 "Lifting of the unit" on page 34
.