User Manual Synertia® RF Generator 49
The information contained in this manual is subject to change by Comet Yxlon without prior notice.
You need two fittings with NPT 3/8 male thread e. g. hose nozzle and
commercially available Teflon® sealing tape.
Wind two to maximum three layers of Teflon® sealing tape tightly onto the
threads.
Observe the winding direction (see
Figure 28).
NOTICE
The Teflon® tape should not overlap the start of the threads.
Safety note 35: Notice - Teflon tape
Figure 28: Fitting with Teflon® sealing tape
Hand-tighten the fittings (approx. three turns) on both water connections and
then tighten them with a spanner (two to three turns).
NOTICE
To avoid damages to the fittings, the maximum tightening torque
is 30 Nm.
Safety note 36: Notice - tightening torque