DGS-3000 Series Layer 2 Managed Gigabit Switch CLI Reference Guide
723
2: swDdmThresholdType
3: swDdmThresholdExceedType
4:
swDdmThresholdExceedOrRecover
The trap is sent when any parameter value
exceeds the warning threshold value or recover
to normal status depending on the configuration
of the trap action.
Binding: 1: swDdmPort
2: swDdmThresholdType
3: swDdmThresholdExceedType
4:
swDdmThresholdExceedOrRecover
1.3.6.1.4.1.171.12.72.4.0.2
This trap is sent when there is an IP address
conflict.
Binding: 1: agentGratuitousARPIpAddr
2: agentGratuitousARPMacAddr
3: agentGratuitousARPPortNumber
4:
agentGratuitousARPInterfaceName
1.3.6.1.4.1.171.12.1.7.2.0.5
The trap is sent when the configuration is
completely saved, uploaded or downloaded.
Binding: 1: unitID
2: agentCfgOperate
1.3.6.1.4.1.171.12.1.7.2.0.9
This trap is sent when the process of upgrading
the firmware via SNMP has finished.
Binding: 1: swMultiImageVersion
1.3.6.1.4.1.171.12.1.7.2.0.7
Power Status change notification. The notification
is issued
when the swPowerStatus changes in the
following cases:
lowVoltage -> overCurrent.
lowVoltage -> working.
lowVoltage -> disconnect.
lowVoltage -> connect.
overCurrent -> lowVoltage.
overCurrent -> working.
overCurrent -> disconnect.
overCurrent -> connect.
working -> lowVoltage.
working -> overCurrent.
working -> connect.
working -> disconnect.
fail -> connect.
fail -> disconnect.
connect -> lowVoltage.
connect -> overCurrent.
connect -> working.
connect -> disconnect.
disconnect -> lowVoltage.
disconnect -> overCurrent.
disconnect -> working.
disconnect -> connect.
Binding : 1: swPowerUnitIndex
2: swPowerID
1.3.6.1.4.1.171.12.11.2.2.2.0.
Power Failure notification. The notification is
issued when the swPowerStatus changes in the
1.3.6.1.4.1.171.12.11.2.2.2.0.
2