Page #136 background imageLoading...
Page #136 background image
Enter/Exit Programming Mode
128 DSM0400 Fixed Mount Area Imager Bar Code Reader
Datalogic 2 of 5 Set Length 2
This feature specifies one of the barcode lengths for
Datalogic 2 of 5 Length Con-
trol on page 126
. Length 2 is the maximum label length if in
Variable Length on
page 111
Mode, or the second fixed length if in
Fixed Length on page 111
Mode.
The length includes the barcode’s check and data characters.
The length can be set from 2 to 50 characte
rs. A setting of 0 specifies to ignore
this length (only one fixed length). For more detailed programming instructions
see "Set Length" on
Chapter 4, References
.
Table 12
provides examples for setting Length 2.
Table 12. Datalogic 2 of 5 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
Ignore This
Length
4 Characters 14 Characters 50 Characters
2
Pad with leading zeroes to
yield two digits
00 04 14 50
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT DATALOGIC 2 OF 5 LENGTH 2 SETTING
5
Scan Two Characters From
Appendix C
‘0’ and ‘0 ‘0’ and ‘4 ‘1’ and ‘4’ ‘5’ AND ‘0’
6 Scan ENTER/EXIT PROGRAMMING MODE
Select Datalogic 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic DSM0400