Enter/Exit Programming Mode
144 DSM0400 Fixed Mount Area Imager Bar Code Reader
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding, fixed length decoding or
no check length decoding for the GS1 DataBar™ Expanded symbology.
Variable Length.
For variable-length decoding, a minimum length may be set.
Fixed Length.
For fixed-length decoding, two different lengths may be set.
GS1 DataBar™ Expanded Length Control = Variable Length
GS1 DataBar™ Expanded Length Control = Fixed Length
DEFAULT
GS1 DataBar™ Expanded Length Control = No check