EasyManua.ls Logo

Datalogic DSM0400 - GS1 Databar Expanded Set Length 2

Datalogic DSM0400
252 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode
146 DSM0400 Fixed Mount Area Imager Bar Code Reader
GS1 DataBar™ Expanded Set Length 2
This feature specifies one of the barcode lengths for
GS1 DataBar™ Expanded
Length Control on page 144
. Length 2 is the maximum label length if in
Variable
Length on page 93
Mode, or the second fixed length if in
Fixed Length on page 93
Mode. Length includes the barcode’s data c
haracters only. The length can be
set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only
one fixed length). For more detailed programming instructions see, "Set
Length" on
Chapter 4, References
.
Table 18
provides examples for setting Length 2.
Table 18. GS1 DataBar™ Expanded Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (ignore sec-
ond length)
07 Characters 52 Characters 74 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT GS1 DataBar™ EXPANDED LEN
GTH 2 SETTING
4
Scan Two Characters From
Appendix C
‘0’ and ‘0’ ‘0’ and ‘7’ ‘5’ and ‘2 ‘7’ and ‘4’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select GS1 DataBar™ Expanded Set Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
74 = Length 2 is 74 Characters

Table of Contents