Enter/Exit Programming Mode
Product Reference Guide 199
QR Code Set Length 1
Specifies one of the bar code lengths for
QR Code Length Control on page 198
.
Length 1 is the minimum
label length if in Variable Length Mode, or the first
fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089
characters in increments of 0001 (pad with zeroes). Always use four digits (e.g.:
scan the barcodes '0', '0', '0', '2' for setting length = 2). For more detailed pro-
gramming instructions see, "Set Length" on
Chapter 4, References
.
Select QR Code Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followe
d by the digits from the Alphanumeric char-
acters in
Appendix C
representing your desired charac-
ter(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
0001 = Length 1 is 1 Character

Table of Contents

Other manuals for Datalogic DSM0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DSM0400 and is the answer not in the manual?

Datalogic DSM0400 Specifications

General IconGeneral
BrandDatalogic
ModelDSM0400
CategoryBarcode Reader
LanguageEnglish

Related product manuals