Enter/Exit Programming Mode
200 DSM0400 Fixed Mount Area Imager Bar Code Reader
QR Code Set Length 2
This feature specifies one of the bar code lengths for
QR Code Length Control on
page 198
. Length 2 is the maximum label length if in Variable Length Mode, or
the second fixed length if in Fixed Length Mode. Characters can be set from
00
01 to 7,089 characters in increments of 0001 (pad with zeroes). Always use
four digits (e.g.: scan the barcodes '0', '0', '0', '2' for setting length = 2). For
more detailed programming instructions see, "Set Length" on
Chapter 4, Refer-
ences
.
Select QR Code Length 2 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followe
d by the digits from the Alphanumeric char-
acters in
Appendix C
representing your desired charac-
ter(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
Length 2 is 7,089 Characters