Enter/Exit Programming Mode
Product Reference Guide 191
PDF417 Set Length 1
Specifies one of the bar code lengths for PDF417. Length 1 is the minimum
label length if in Variable Length Mode, or the first fixed length if in Fixed
Length Mode. Length includes the bar code’s data characters only. Characters
can be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01.
Any value greater than 2,710 will be considered to be 2,710. Always use four
digits (e.g.: scan the barcodes '0', '0', '0', '2' for setting length = 2). For more
detailed programming instructions see "Set Length" on
Chapter 4, References
.
Select PDF417 Length 1 Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
left followe
d by the digits from the Alphanumeric char-
acters in
Appendix C
representing your desired charac-
ter(s). End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
0001 = Length 1 is 1 Character

Table of Contents

Other manuals for Datalogic DSM0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DSM0400 and is the answer not in the manual?

Datalogic DSM0400 Specifications

General IconGeneral
BrandDatalogic
ModelDSM0400
CategoryBarcode Reader
LanguageEnglish

Related product manuals