EasyManuals Logo

Datalogic DSM0400 User Manual

Datalogic DSM0400
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #166 background imageLoading...
Page #166 background image
Enter/Exit Programming Mode
158 DSM0400 Fixed Mount Area Imager Bar Code Reader
Plessey Check Character Calculation
Enables/Disables calculation and verification of an optional Plessey
check character.
Plessey Check Character Calculation = Disable
Plessey Check Character Calculation =
Enable Plessey std. check char. verification
DEFAULT
Plessey Check Character Calculation =
Enable Anker check char. verification
Plessey Check Character Calculation =
Enable Plessey std. and Anker check char verification
Plessey Check Character Transmission
Enables/disables transmission of an MSI check character.
Plessey Check Character Transmission = Disable
Plessey Check Character Transmission = Enable
DEFAULT

Table of Contents

Other manuals for Datalogic DSM0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DSM0400 and is the answer not in the manual?

Datalogic DSM0400 Specifications

General IconGeneral
BrandDatalogic
ModelDSM0400
CategoryBarcode Reader
LanguageEnglish

Related product manuals