158 DSM0400 Fixed Mount Area Imager Bar Code Reader
Plessey Check Character Calculation
Enables/Disables calculation and verification of an optional Plessey
check character.
Plessey Check Character Calculation = Disable
Plessey Check Character Calculation =
Enable Plessey std. check char. verification
DEFAULT
Plessey Check Character Calculation =
Enable Anker check char. verification
Plessey Check Character Calculation =
Enable Plessey std. and Anker check char verification
Plessey Check Character Transmission
Enables/disables transmission of an MSI check character.
Plessey Check Character Transmission = Disable
Plessey Check Character Transmission = Enable