Enter/Exit Programming Mode
Product Reference Guide 151
Code 93 Set Length 2
This feature specifies one of the barcode lengths for Code 93. Length 2 is the
maximum label length if in
Variable Length on page 93
Mode, or the second fixed
length if in
Fixed Length on page 93
Mode. Length includes the barcode’s check,
data, and full-ASCII shift characters. The length does not include start/stop
c
haracters. The length can be set from 1 to 50 characters. A setting of 0 speci-
fies to ignore this length (only one fixed
length). For more detailed program-
ming instructions see, "Set Length" on
Chapter 4, References
.
Table 20
provides examples for setting Length 2.
Table 20. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Length)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix C
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and
not save the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
50 = Length 2 is 50 Characters

Table of Contents

Other manuals for Datalogic DSM0400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DSM0400 and is the answer not in the manual?

Datalogic DSM0400 Specifications

General IconGeneral
BrandDatalogic
ModelDSM0400
CategoryBarcode Reader
LanguageEnglish

Related product manuals