EasyManua.ls Logo

Eaton Rapid Link 5 - Page 184

Eaton Rapid Link 5
249 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Parameter list
8.4 Parameter groups for RASP5
180 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
P1-10 Motor Nom Speed Motor rated speed
P1-10 = 0: the speed of the motor will be displayed in Hz.
P1-10 > 0: the speed related parameters (f-max, f-min etc.)
will be displayed in rpm. The slip compensation is also acti-
vated, where the shaft speed of the motor is maintained
under varying load conditions by compensating for the load-
dependent slip of the motor. If “Motor Nom Speed” = motor
synchronous speed (e.g. 3000rpm for a 2-pole 50Hz motor),
the speed can be displayed in rpm without activating the slip
compensation.
rpm 0 30000 0
P1-11 V-Boost Voltage is used to increase the applied motor voltage at low
output frequency, in order to improve low speed and starting
torque. Excessive voltage boost levels may result in incre-
ased motor current and temperature,
and forced ventilation may be required.
An automatic setting (Auto) is also possible, whereby the
drive will automatically adjust this parameter based on the
motor parameters measured during an Autotune.
Note:
This parameter will only be enabled when using speed
control (extended V/f, P6-01 = 6).
% 0 40 0
P1-12 f-Fix1 Preset Fixed Frequency 1
Value can be adjusted between f-min and f-max.
Selection via a digital control signal.
Hz P1-02 P1-01 10.0Hz
P1-13 SEN Config Select Configuration of sensor inputs with a fix set of combinations 0 12 1
P1-14 Access key Entry of the password to get access to the extended para-
meter set.
The value to be put in is determined by the level to be
accessed.
Level 2 (access to parameter groups 0 to 8):
P1-14 = P2-32 (default: 101)
0 65535 0
Parameter Designation Description Unit Min Max DS