9 Communication
9.1 A S - In ter fa ce
200 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
9.1.13 Controlling RASP5 via the AS-Interface
Table 50: Controlling RASP5
The START signal or enable for the requested operating direction is
issued through DQ0 (FWD) or DQ1 (REV).
The fixed frequencies f-Fix1 to f-Fix4 (digital setpoint value memory) are
called up in binary code through outputs DQ2 and DQ3.
If DQ2 and DQ3 are not activated, the frequency set in f-Fix1 is issued.
Function Signal to RASP5
Outputs Inputs
DQ0 DQ1 DQ2 DQ3 DI0 DI1 DI2 DI3
No controller enable 0 0
Anticlockwise rotating field (REV) 0 1
Clockwise rotating field (FWD) 1 0
No controller enable/reset 1 1
f-Fix1 (P1-12 = 10 Hz) 0 0
f-Fix2 (P2-01 = 30 Hz) 1 0
f-Fix3 (P2-02 = 40 Hz) 0 1
f-Fix4 (P2-03 = 50 Hz) 1 1
Automatic mode 1
No automatic mode 0
Accumulative error 0
No accumulative error 1
External input SEN I1
no signal 0
Signal available 1
External input SEN I2
no signal 0
Signal available 1