2.15 Thermistor and motor cable monitoring
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com 79
2.15 Thermistor and motor cable monitoring
In RAMO5 and RASP5, the reaction of the thermistor fitted in the motor and
the motor cable are set using parameter P2-27.
Table 16: Parameter P2-27 for thermistor and motor cable monitoring
a Bridge in the motor connector:
Only monitors the plugged-in status of the motor
connector.
b Bridge in the motor terminal box:
Monitors the plugged-in status of the motor connector and
the motor cable connection.
c Thermistor connection:
Monitors the plugged-in status of the motor plug, the motor
cable connection, and the thermistor (or temperature
switch, Thermo-Click) in the motor.
Figure 36: Thermistor monitoring
Para-
meter
Designation Description Unit Min Max DS
P2-27 Action@
Motor thermistor
fault
Device response (depending on device)
after “Thermistor Fault” occurs.
0: Disabled (OFF)
1: Enabled (ON)
0 1 1
ATTENTION
The setting of parameter P2-27 may only be changed by trained
specialist personnel!
58173PE
T1 T2
M 3 ∼
ϑ
UVWPE
P2-27