6 RASP5 speed controller
6.4 Specific technical data
138 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
6.4 Specific technical data
The following tables show the technical data of the RASP5 speed controller
in the individual power classes with the assigned motor power.
→
The motor power allocation is based on the rated operational
current.
→
The motor power indicates the respective active power output
to the drive shaft of a normal, four pole, internally or externally
ventilated three-phase asynchronous motor with 1500 rpm
(at 50 Hz) and 1800 rpm (at 60 Hz).
Symbol Unit RASP5-2… RASP5-4… RASP5-5… RASP5-8…
Rated current (I
e
)I
e
A 2.4 4.3 5.6 8.5
Overload current for 60 s every
600 s at 40 °C
I
L
A 3.6 6.5 8.4 12.75
Startup current for 2 s
every 20 s at 40 °C
I
L
A 4.8 8.6 11.2 17
Apparent power at 400 V rated
operation
SkVA
1.84 3.27 4.24 6.49
Assigned motor power at 440 V,
60 Hz
PkW0.75 1.5 2.2 4
PHP1 2 3 5
Setting range
current limitation (P1-08)
l
2
A 0.2 - 2.4 0.4 - 4.3 0.5 - 5.6 0.8 - 8.5
Power supply side (primary side)
Number of phases 3 3 3 3
Rated voltage U
LN
V 380 V - 15 % - 480 V + 10 %, 50/60 Hz
(380 - 480 V ±0 %, 45 - 66 Hz ±0 %)
Input current I
LN
A 2.5 4.1 5.3 7.8
Braking
Braking value I/I
e
% ≦ 30 ≦ 30 ≦ 30 ≦ 30
Switch-on threshold for the
braking transistor
U
DC
VDC 765 765 765 765