8 Parameter list
8.4 Parameter groups for RASP5
184 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
P2-34 TCP Enable Service Cyber Security
Enable communications interfaces
P2-34 is a bitmap parameter where;
0000b: All services disabled off
xxx1b: reserved
xx1xb: TFTP/FTP server enable
x1xxb: reserved
0 15 0
P2-35
P2-36 Save parameter
@24V-ext.
List of defined parameters
1: If control voltage is present, the Parameters will be saved.
After that, the parameter is automatically set to 0.
0 1 0
P2-37 Spin Start Enable Spin Start Enable
The drive starts from the detected motor speed. A short start
delay is possible if the rotor is stationary.
0: Spin Start Off
1: Spin Start On
0 1 0