1 Rapid Link 5 system
1.5 Compliance with UL standards
Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com 23
1.5.1.2 RASP (file E226333)
Electrical Ratings:
Ratings (continued)
Environmental Ratings:
Maximum ambient air temperature 55°C.
Enclosure Type 12
TECHNICAL CONSIDERATIONS
USL - indicates investigated to United States Standard UL61800-5-1 - listed.
CUL - indicates investigated to Canadian Standard CSA 22.2 No. 274 - listed
General:
These devices are solid state variable/speed AC drive inverters which convert a fixed frequency three phase input
voltage to a 3-phase, variable frequency, variable voltage output. The inverter automatically contains the required
volts-Hz ratio allowing the AC motor to run at its optimum efficiency and provide constant torque capability through
the motor speed range.
The power conversion equipment provides solid state motor overload protection.
Over-current function was evaluated. Maximum current limit is 150 percent of FLC. The adjustable range is 0 to 150
percent of FLC.
Drive is provided with solid state short circuit protection circuit which is the same throughout the series. Current
MODEL – 400V range INPUT OUTPUT
(3 phase) (3 phase)
Frame
size
Model Number FLA FLA Power
kW
Power
HP
1A RASP5-2… 2.4 2.4 0.75 1.0
1A RASP5-4… 4.3 4.3 1.5 2.0
1A RASP5-5… 5.6 5.6 2.2 3.0
1B RASP5-8… 8.5 8.5 4.0 5.0
Input voltage 380-480/277 VAC, 50/60Hz, Output voltage 20-500 VAC, 0-500HZ
A: external fan not fit
B: external fan fitted
Terminals – All Models
Qty Maximum ratings
Sensor supply 3 24V 100mA
Motor Brake
1 600mA 400V (6A < 120mS)
Short Circuit Rating (kA)
RASP5 100kA When protected by Class J fuses
10kA When protected by Circuit breaker (Type C)
65kA When protected by Type E combination Motor Controller
RASP5-xxR
(repair switch)
10kA When protected by Class J fuses
When protected by Circuit breaker (Type C)
When protected by Type E combination Motor Controller