2 Engineering
2.13 External brake
76 Rapid Link 5 · RAMO5 · RASP5 05/20 MN034004EN www.eaton.com
Table 12: Advanced Mode (Advanced Mode): P3-01 = 1
Mechanical brake (actuation) for RAMO5
The brake is switched off with the stop command according to the decelera-
tion time.
The brake is released with the Start command.
The delay is set using parameters P3-04 and P3-05.
Table 13: Parameters for brake for RAMO5
Control commands Action of the drive
Start signal Enable device
→ The frequency increases to the value set in P3-02.
→ The current and/or torque are monitored until they reach the level set in P3-04.
→ The brake is released.
→ The output frequency remains at the value set in P3-02 for the time (delay) set in
P3-05.
→ The ramps are on the set point. The drive continues the ramp up to the setpoint value.
Normal operation - drive is running
Stop order The frequency drops and the brake is applied when the output frequency falls below the
value set in P3-03.
→ The drive continues the ramp to a standstill.
→ The output of the drive is disabled.
Para-
meter
Designation Description Unit
P3-04 Brake Release Delay Determines the time before the mechanical brake is
released.
s
P3-05 Brake Apply Delay Determines the time between the signal to close the
mechanical brake and the drive being disconnected.
s