EasyManua.ls Logo

Edge-Core EAP8518 - Page 147

Edge-Core EAP8518
261 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C
HAPTER
17
| SNMP Commands
– 147 –
snmp-server
community
This command defines the community access string for the Simple Network
Management Protocol. Use the no form to remove the specified community
string.
SYNTAX
snmp-server community string [ro | rw]
no snmp-server community string
string - Community string that acts like a password and permits
access to the SNMP protocol. (Maximum length: 23 characters, case
sensitive)
ro - Specifies read-only access. Authorized management stations
are only able to retrieve MIB objects.
rw - Specifies read/write access. Authorized management stations
are able to both retrieve and modify MIB objects.
DEFAULT SETTING
public - Read-only access. Authorized management stations are only
able to retrieve MIB objects.
private - Read/write access. Authorized management stations are able
to both retrieve and modify MIB objects.
COMMAND MODE
Global Configuration
COMMAND USAGE
If you enter a community string without the ro or rw option, the default is
read only.
EXAMPLE
AP(config)#snmp-server community alpha rw
AP(config)#
snmp-server
contact
This command sets the system contact string. Use the no form to remove
the system contact information.
SYNTAX
snmp-server contact string
no snmp-server contact
string - String that describes the system contact.
(Maximum length: 255 characters)
DEFAULT SETTING
None